CompanyBanner

Flexible flat cable banner

Flexible flat cable
 

 

BulletStructure
Back to top Up Arrow
Chart
     
 
Pitch between
conductors
Number of
conductor
Terminal length
Insulation length
Whole width
0.50 ± 0.05
7 to 60
4,5,6 ±1
40 mm or more
0.50(N+1)
±0.07
Total pitch
Margin width
Reinforcing tape
length
Terminal thickness
Conductor
width
0.50(N-1)±0.05
0.50±0.10
0.3±0.05(Excluding solderable terminal face)
0.30 ± 0.03
Total length
(Width (mm) x thickness (mm))
40 to 250±5
 0.3 x 0.035
 
BulletSpecifications
Back to top Up Arrow

FFC Chart
Type 1: Shield material connected to ground wire (GND type)

 
Product name
(UL printing color)
Thickness of film
Thickness of base film
Thickness of adhesive
UL rating
Features
TC7901N(blue)
37µm
12µm
25µm
80°C 30V
-

 

 

 

 
Formation of the conductor material

 
Product name
Width (mm)
Thickness
Conductor pitch
0335
0.3
35µm
0.5
 

Formation of the reinforcing material

 
Product name
Thickness of film
Thickness of base film
Thickness of adhesive
UL rating
TC7919F
228µm
(sky blue)
188µm
(transparent)
40µm
(sky blue)
for FFC with a conductor thickness of 50 µm or less for FPC
 

Impedance Product Type

Impedance FCC Terminal

*The size specification of FFC is that of a 0.5-mm pitch FFC (Number of conductor omitted).


Impedance FFC Terminal Detail

 
Conductor name
Size (mm)
Conductor pitch
Permissible current (A)
Conductor resistance (Ω/M)
0335
228µm(sky blue)
0.5
0.3 x 0.035
1.75 or less
Permissible current is reference value.
 

BulletTechnical Data
Back to top Up Arrow


CAUTION